VIQUA
Viqua Sterilight VT1 Tap UV System 1 GPM 3/8"-1/2" NPT
- SKU:
- VT1
- Condition:
- New
- Weight:
- 4.00 LBS
- Shipping:
- Calculated at Checkout
Description
PRODUCT DOCUMENTATION
Viqua VT1 is a compact single tap POU (point of use) UV desinfection system designed for up to 1 gpm (4 lpm) flow rate. Perfect for a single faucet, water fountain or low-flow application. The VT1 replaces the Sterilight SC1 System.
FEATURES & BENEFITS
- Designed to destroy Bacteria, Viruses and inactivate chlorine-resistant parasites such as Cryptosporidium and Giardia
- Stainless steel chamber to prolong UV intensity and eliminate ultraviolet light degradation
- Easy to maintain and service
- The BA-VT power supply visually displays the remaining lamp life
- UV lamp can be changed without interrupting the water flow
SPECIFICATION
- Disinfection Flow Rate: 30 mJ/cm2 @ 1.0 gpm
- Disinfection Flow Rate: 40 mJ/cm2 @ 0.7 gpm
- The UV Lamp Life: 9000 hours of continuous purification
- Connection Size: 3/8"-1/2" NPT
- Power Consumption: 13W
- Voltage: 100-240V/50/60 Hz
- Maximum Operating Pressure: 125 PSI
REPLACEMENT PARTS
- Replacement UV Lamp: S212RL
- Replacement UV Sleeve: QS-212
- Replacement Lamp & Combo Kit: S212-QL
- Replacement Power Supply: BA-VT
- Replacement O-Ring: 410867
- Retaining Nut: RN-001
WATER QUALITY REQUIREMENTS PRIOR TO UV TREATMENT
- Iron < 0.3 ppm (0.3 mg/L)
- Manganese < 0.05 ppm (0.05 mg/L)
- Hardness < 7gpg
- Tannins < 0.1 ppm (0.1 mg/L)
- Turbidity < 1NTU UV transmittance > 75%
Warranty Information
One-Year Limited Warranty for Lamps, Sleeves and UV Sensors VIQUA warrants lamps, sleeves and UV sensors to be free from defects in material and workmanship for a period of one (1) year from the date of purchase. During this time, VIQUA will repair or replace, at its option, any defective parts covered by the warranty.Your dealer will process your claim and advise whether the defective item needs to be returned for failure analysis. IMPORTANT NOTE: Use only genuine Sterilight® replacement lamps and sleeves in your system. Failure to do so may seriously compromise disinfection performance and affect warranty coverage. General Conditions and Limitations None of the above warranties cover damage caused by improper use or maintenance, accidents, acts of God or minor scratches or imperfections that do not materially impair the operation of the product. The warranties also do not cover products that are not installed as outlined in the applicable Owner’s Manual. Parts repaired or replaced under these warranties will be covered under warranty up to the end of the warranty period applicable to the original part. The above warranties do not include the cost of shipping and handling of returned items The limited warranties described above are the only warranties applicable to the Sterilight® range of products. These limited warranties outline the exclusive remedy for all claims based on a failure of or defect in any of these products, whether the claim is based on contract, tort (including negligence), strict liability or otherwise. These warranties are in lieu of all other warranties whether written, oral, implied or statutory. Without limitation, no warranty of merchantability or of fitness for a particular purpose shall apply to any of these products. VIQUA does not assume any liability for personal injury or property damage caused by the use or misuse of any of the above products. VIQUA shall not in any event be liable for special, incidental, indirect or consequential damages. VIQUA’s liability shall, in all instances, be limited to repair or replacement of the defective product or part and this liability will terminate upon expiration of the applicable warranty period.